Vibration Meter
āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļ§āļąāļ”āļ„āļ§āļēāļĄāļŠāļąāđˆāļ™āļŠāļ°āđ€āļ—āļ·āļ­āļ™ VM6360

✅ āļŠāđˆāļ§āļ‡āļāļēāļĢāļ§āļąāļ” Acceleration (Peak) 0.1 āļ–āļķāļ‡ 400 m/sÂē
✅ āļŠāđˆāļ§āļ‡āļāļēāļĢāļ§āļąāļ” Velocity (RMS) 0.01 āļ–āļķāļ‡ 400.0 mm/s
✅ āļŠāđˆāļ§āļ‡āļāļēāļĢāļ§āļąāļ” Displacement (Peak – Peak) 0.001 āļ–āļķāļ‡ 4.000 mm
✅ āļŠāđˆāļ§āļ‡āļ„āļ§āļēāļĄāļ–āļĩāđˆ 10Hz āļ–āļķāļ‡ 1KHz
✅ āļ„āļ§āļēāļĄāđāļĄāđˆāļ™āļĒāļģ Âą5% +2 digits
✅ āļāļēāļ™āđāļĄāđˆāđ€āļŦāļĨāđ‡āļāļŠāļģāļŦāļĢāļąāļšāđ€āļ‹āđ‡āļ™āđ€āļ‹āļ­āļĢāđŒāđāļĨāļ° Piezoelectric accelerometer

#VibrationMeter
#āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļ§āļąāļ”āļ„āļ§āļēāļĄāļŠāļąāđˆāļ™āļŠāļ°āđ€āļ—āļ·āļ­āļ™

Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery. Specifically designed for present measuring various mechanical vibration. So as to provide the data for the quality control, run time and equipment upkeep.

* In accordance with ISO 2954, used for periodic measurements, to detect out-of-balance, misalignment and other mechanical faults in rotating machines.
* Specially designed for easy on site vibration measurement of all rotating machinery for quality control,commissioning, and predictive maintenance purposes.
* Individual high quality ccelerometer for accurate and repeatable measurements.
* Wide frequency range (10Hz~10kHz) in acceleration mode.
* Optional headphones for use as electronic stethoscope.
* Bearing condition monitoring function.
* Use “USB data output” and “RS-232 data output” to connect with PC.
* Provide “ BT â„Ē data output” choice.
Sensor   Piezoelectric Accelerometer
  Measuring Range
  Acceleration: 0.1~400 m/sÂē   0.3~1312 ft/sÂē   0.0~40 g   Equivalent Peak
  Velocity: 0.01~400 mm/s   0.004~16.0 inch/s   True RMS
  Displacement: 0.001~4.0 mm   0.04~160.0 mil   Equivalent Peak-peak
  Frequency Range   Acceleration: 10 Hz ~ 1k Hz   10 Hz ~ 10k Hz
  Velocity: 10 Hz ~ 1k Hz
  Displacement: 10 Hz ~ 1k Hz
  Accuracy   5 % of Reading + 2 digits
  Metric / Imperial Conversion
  Analogue Output   AC Output 0~2.0 V Peak Full Scale (Load Resistance: Above 10k)
  Max. Value Hold
  Power Off   Manual Power Off or Auto Power Off
  Battery Indicator   Low Battery Indicator
  Data Output   USB, RS-232, BT
  Operating Conditions   Temperature: 0~50 °C Humidity: <90 %RH
  Power Supply   4 x 1.5V AAA size (UM-4) Battery
  Dimensions   124 x 62x 30 mm
  Weight   120 g (Not Including Batteries)

Standard Accessories:

1. Main Unit

2. Magnetic Suction Seat

3. Piezoelectric Transducer

4. Probe (Cone)

5. Probe (Spherical)

6. Carrying Case

7. Manual Book

Optional Accessories:

1. Headset

2. USB, RS-232 data cable with software

3. BT data out put with software

āļŠāļ­āļšāļ–āļēāļĄāđ€āļžāļīāđˆāļĄāđ€āļ•āļīāļĄ

Tonan Asia Autotech Co., Ltd.

Line: @tonanasia

Tel: 0-2565-9370-4

E-mail: sales@tonanasia.com

Website: https://www.tonanasia.com

Google Map: https://goo.gl/maps/SM3p4YGQ6qC2


āđ€āļŦāļ•āļļāļœāļĨāļ”āļĩāđ† āļ—āļĩāđˆāļ•āđ‰āļ­āļ‡āđ€āļĨāļ·āļ­āļāļ‹āļ·āđ‰āļ­āļŠāļīāļ™āļ„āđ‰āļēāļˆāļēāļāđ€āļĢāļē

1. FAST DELIVERY
  1. FAST DELIVERY āļšāļĢāļīāļāļēāļĢāļˆāļąāļ”āļŠāđˆāļ‡āļĢāļ§āļ”āđ€āļĢāđ‡āļ§

āđ€āļĢāļēāđƒāļŦāđ‰āļ„āļ§āļēāļĄāļŠāļģāļ„āļąāļāđƒāļ™āļāļēāļĢāļˆāļąāļ”āļŠāđˆāļ‡āļŠāļīāļ™āļ„āđ‰āļēāļ—āļĩāđˆāļĢāļ§āļ”āđ€āļĢāđ‡āļ§ āļ•āļĢāļ§āļˆāđ€āļŠāđ‡āļ„āļ„āļļāļ“āļ āļēāļžāļŠāļīāļ™āļ„āđ‰āļēāļāđˆāļ­āļ™āļŠāđˆāļ‡āļ—āļļāļāļ„āļĢāļąāđ‰āļ‡

2. WARRANTY

2. Guarantee āļĢāļąāļšāļ›āļĢāļ°āļāļąāļ™āļ„āļļāļ“āļ āļēāļž

āļŠāļīāļ™āļ„āđ‰āļēāļ—āļļāļāļŠāļīāđ‰āļ™āļĄāļĩāļāļēāļĢāļĢāļąāļšāļ›āļĢāļ°āļāļąāļ™ 1 āļ›āļĩ (āļ•āļēāļĄāđ€āļ‡āļ·āđˆāļ­āļ™āđ„āļ‚āļ—āļĩāđˆāļāļģāļŦāļ™āļ”)

3. Consult Free

3. Free Consult āļšāļĢāļīāļāļēāļĢāļ•āļ­āļšāļ„āļģāļ–āļēāļĄāļĨāļđāļāļ„āđ‰āļē

āđ€āļĢāļēāļĄāļĩāļžāļ™āļąāļāļ‡āļēāļ™āļ‚āļēāļĒ āļ„āļ­āļĒāļ”āļđāđāļĨ āļ•āļ­āļšāļ„āļģāļ–āļēāļĄāļ—āļļāļāļ‚āđ‰āļ­āļŠāļ‡āļŠāļąāļĒāđ€āļāļĩāđˆāļĒāļ§āļāļąāļšāļŠāļīāļ™āļ„āđ‰āļēāđ„āļ”āđ‰āđ€āļ›āđ‡āļ™āļ­āļĒāđˆāļēāļ‡āļ”āļĩ āđāļĨāļ°āļĄāļĩāļšāļĢāļīāļāļēāļĢāļŠāļēāļ˜āļīāļ•āļāļēāļĢāđƒāļŠāđ‰āļ‡āļēāļ™ āļŸāļĢāļĩ


4. After Sale Service

4. AFTER SALE SERVICE āļšāļĢāļīāļāļēāļĢāļ”āļđāđāļĨāļŦāļĨāļąāļ‡āļāļēāļĢāļ‚āļēāļĒ

āļŠāļīāļ™āļ„āđ‰āļēāļĄāļĩāļ›āļąāļāļŦāļēāđ„āļĄāđˆāļ•āđ‰āļ­āļ‡āļāļąāļ‡āļ§āļĨ āđāļˆāđ‰āļ‡āđ€āļ„āļĨāļĄāļŠāļīāļ™āļ„āđ‰āļē āļ•āļīāļ”āļ•āđˆāļ­āļžāļ™āļąāļāļ‡āļēāļ™āļ”āļđāđāļĨāļŦāļĨāļąāļ‡āļāļēāļĢāļ‚āļēāļĒāđ„āļ”āđ‰āļ—āļąāļ™āļ—āļĩ āļŦāļĢāļ·āļ­ āđ‚āļ—āļĢ 0-2565-9370-4

5. Calibration Service

5. Calibration Service āļšāļĢāļīāļāļēāļĢāļŠāļ­āļšāđ€āļ—āļĩāļĒāļš

āđ€āļĢāļēāļĄāļĩāļšāļĢāļīāļāļēāļĢāļŠāļ­āļšāđ€āļ—āļĩāļĒāļšāđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļĄāļ·āļ­āļ§āļąāļ” āļ”āđ‰āļ§āļĒ LAB āļĄāļēāļ•āļĢāļāļēāļ™ ISO-17025

6. Seminar and Training

6. Seminar and Training āļāļēāļĢāļˆāļąāļ”āļŠāļąāļĄāļĄāļ™āļēāđāļĨāļ°āļāļķāļāļ­āļšāļĢāļĄ

āđ€āļĢāļēāļŠāļēāļĄāļēāļĢāļ–āļˆāļąāļ”āļāļķāļāļ­āļšāļĢāļĄāđāļĨāļ°āļŠāļąāļĄāļĄāļ™āļēāđƒāļŦāđ‰āļ„āļ§āļēāļĄāļĢāļđāđ‰ āļ—āļąāđ‰āļ‡āđƒāļ™āđāļĨāļ°āļ™āļ­āļāļŠāļ–āļēāļ™āļ—āļĩāđˆ